EasyManuals Logo

3M 965DSP User Manual

3M 965DSP
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #87 background imageLoading...
Page #87 background image
87
Numeric
Code
0 x 41
0 x 50
0 x 51
0 x 53
0 x 54
Definition
Signal Lost
Frame Lost
Margin Lost
Cell Delineation
Lost
Meaning
Interruption in the path between the
modems lasting at least 2.5 seconds
Loss of ADSL framing lasting at
least 2.5 seconds
Required noise margin was lost for
at least 2.5 seconds
ATM cell delineation lost for at
least 2.5 seconds
Numeric
Code
0 x 21
0 x 22
0 x 07
0 x 08
Definition
Open Rejected
Open Failed
Connect Timeout
Close Timeout
Meaning
Illegal parameters or modem not
ready
Modem failure detected during
activation process
Modem did not connect within 40
seconds
Modem link not properly closed
Common error conditions and their causes are listed
in the table below. Contact 3M Technical Service
for any undefined codes.
Link Timeout Messages
Error conditions causing modem timeouts are displayed
as ‘Connection: Timed Out’ with numeric codes and
abbreviated text definitions.
Common error conditions and their causes are listed in
the table below. Contact 3M Technical Service for any
undefined codes.