49
K-Test Error: R1+R2<100*Rloop
The 965DSP checks to see that the sum of the faults is
more than 100 times the loop resistance. The 965DSP
will display the following screen if the sum of the faults
is less than 100 times the loop resistance.
Press [Tab] to continue even though the fault values
are too low. This may result in reduced accuracy of
the measurement.
Press [Enter] to repeat the K-Test, starting with the
Open Far-End” screen. You should first find a new pair
in the faulted cable with higher value fault resistances.