60
The screen shows the fault resistance beside the 
resistor symbol. The wire gauge, temperature and 
section number are displayed above the bottom bar. 
If the Yield Sign 
 shows beside the results, this 
indicates a possible marginal result (due to noise or 
other line conditions). 
Press [Tab] to show readings in Ohms instead of 
distance.  Press again to return to distance. Press 
[Enter] to repeat the fault locate on the same pair or 
the [Return] key to test a new pair. Press [Setup] to 
change the Gauge or Temperature. 
If there is a problem with the connection, you will 
see the “Hookup Error” screen. 
There are three possible hookup errors: 1) the fault is 
greater than 20 M
Ω, 2) the red/green strap is bad, or 
3) the red/yellow strap is bad.
The screen will show the combination of errors that 
have been detected.  Correct the errors and press the 
[Enter] key to repeat the hookup test.