68
2) The temperature is unknown. In this case the
screen will show the entered Distance to Strap (or
the sum of all sections) in the main result box, and
will show the calculated temperature at the bottom.
The screen also shows the number of the faulted
section at the lower right side of the screen.
If the calculated temperature is much different than
the expected temperature, you should suspect that
the entered DTS or the entered section information is
incorrect.