272 Call logging (CL)
syd-0200/3.0 – I7.9 – 11.2009
Date and time of start of connection
Entry for the time of the start of connection at the logging PBX/PISN.
In the case of forwarded calls the time logged is the time as of which the trans-
ferred call begins.
Duration of connection
Entry for the duration of a connection by the logging PBX/PINX.
The entry for unanswered calls is 0.
Call charges
In the case of an ISDN connection, the call charge information supplied with the
call is entered here.
In the case of an analogue connection, the metering pulses are converted and
entered.
Metering pulses
In the case of an ISDN connection, the call charge information supplied with the
call is converted and entered.
In the case of an analogue connection the metering pulses are entered.
Network interface number
The primary channel group "0" is output in position "c", the trunk card number in
position "bb" and the network interface number in position "pp".
Example:
00201 Trunk card in system slot 2. Network interface 1.
00504 Trunk card in system slot 5. Network interface 4.