Parameters 101
Summary of parameter groups
Group Contents Page
01 Actual values Basic signals for monitoring the drive. 103
03 Input references Values of references received from various sources. 106
04 Warnings and faults Information on warnings and faults that occurred last. 107
05 Diagnostics Various run-time-type counters and measurements related to drive
maintenance.
108
06 Control and status words Drive control and status words. 110
07 System info Drive hardware and firmware information. 116
10 Standard DI, RO Configuration of digital inputs and relay outputs. 117
11 Standard DIO, FI, FO Configuration of the frequency input. 122
12 Standard AI Configuration of standard analog inputs. 124
13 Standard AO Configuration of standard analog outputs. 128
15 I/O extension module Configuration of the I/O extension module installed in slot 2. 133
19 Operation mode Selection of local and external control location sources and
operating modes.
141
20 Start/stop/direction Start/stop/direction and run/start enable signal source selection;
positive/negative reference enable signal source selection.
142
21 Start/stop mode Start and stop modes; emergency stop mode and signal source
selection; DC magnetization settings.
147
22 Speed reference selection Speed reference selection; motor potentiometer settings. 154
23 Speed reference ramp Speed reference ramp settings (programming of the acceleration
and deceleration rates for the drive).
162
24 Speed reference
conditioning
Speed error calculation; speed error window control configuration;
speed error step.
163
25 Speed control Speed controller settings. 164
28 Frequency reference chain Settings for the frequency reference chain. 167
30 Limits Drive operation limits. 174
31 Fault functions Configuration of external events; selection of behavior of the drive
upon fault situations.
177
32 Supervision Configuration of signal supervision functions 1…6. 184
34 Timed functions Configuration of the timed functions. 191
35 Motor thermal protection Motor thermal protection settings such as temperature
measurement configuration, load curve definition and motor fan
control configuration.
199
36 Load analyzer Peak value and amplitude logger settings. 206
37 User load curve Settings for user load curve. 210
40 Process PID set 1 Parameter values for process PID control. 213
41 Process PID set 2 A second set of parameter values for process PID control. 229
45 Energy efficiency Settings for the energy saving calculators as well as peak and
energy loggers.
231
46 Monitoring/scaling settings Speed supervision settings; actual signal filtering; general scaling
settings.
236
47 Data storage Data storage parameters that can be written to and read from
using other parameters’ source and target settings.
238
49 Panel port communication Communication settings for the control panel port on the drive. 239