310 Additional parameter data
21.16 Pre-heating current Real 0.0…30.0 % 10 = 1%
21.18 Auto restart time Real 0.0, 0.1…10.0 s 10 = 1 s
21.19 Scalar start mode List 0…4 - 1 = 1
21.21 DC hold frequency Real 0.00…1000.00 Hz 100 = 1 Hz
21.22 Start delay Real 0.00…60.00 s 100 = 1 s
21.23 Smooth start Real 0…2 - 1 = 1
21.24 Smooth start current Real 10.0…100.0 % 100 = 1%
21.25 Smooth start speed Real 2.0…100.0 % 100 = 1%
21.26 Torque boost current Real 15.0…300.0 % 100 = 1%
21.34 Force auto restart List 0…1 - 1 = 1
22 Speed reference selection
22.01 Speed ref unlimited Real -30000.00…30000.00 rpm 100 = 1 rpm
22.11 Ext1 speed ref1 Analog
src
--1 = 1
22.18 Ext2 speed ref1 Analog
src
--1 = 1
22.21 Constant speed function PB 0000h…FFFFh - 1 = 1
22.22 Constant speed sel1 Binary
src
--1 = 1
22.23 Constant speed sel2 Binary
src
--1 = 1
22.24 Constant speed sel3 Binary
src
--1 = 1
22.26 Constant speed 1 Real -30000.00…30000.00 rpm 100 = 1 rpm
22.27 Constant speed 2 Real -30000.00…30000.00 rpm 100 = 1 rpm
22.28 Constant speed 3 Real -30000.00…30000.00 rpm 100 = 1 rpm
22.29 Constant speed 4 Real -30000.00…30000.00 rpm 100 = 1 rpm
22.30 Constant speed 5 Real -30000.00…30000.00 rpm 100 = 1 rpm
22.31 Constant speed 6 Real -30000.00…30000.00 rpm 100 = 1 rpm
22.32 Constant speed 7 Real -30000.00…30000.00 rpm 100 = 1 rpm
22.41 Speed ref safe Real -30000.00…30000.00 rpm 100 = 1 rpm
22.51 Critical speed function PB 00b…11b - 1 = 1
22.52 Critical speed 1 low Real -30000.00…30000.00 rpm 100 = 1 rpm
22.53 Critical speed 1 high Real -30000.00…30000.00 rpm 100 = 1 rpm
22.54 Critical speed 2 low Real -30000.00…30000.00 rpm 100 = 1 rpm
22.55 Critical speed 2 high Real -30000.00…30000.00 rpm 100 = 1 rpm
22.56 Critical speed 3 low Real -30000.00…30000.00 rpm 100 = 1 rpm
22.57 Critical speed 3 high Real -30000.00…30000.00 rpm 100 = 1 rpm
22.71 Motor potentiometer function List 0…3 - 1 = 1
22.72 Motor potentiometer initial
value
Real -32768.00…32767.00 - 100 = 1
22.73 Motor potentiometer up source Binary
src
--1 = 1
No. Name Type Range Unit FbEq32