270 ACS550 User’s Manual
Technical data
Screw-on terminal lugs
Use the following procedure to attach cables
if screw-on terminal lugs are supplied and
the cable size is 95 mm
2
(3/0 AWG) or
larger.
1. Attach the supplied screw-on lugs to the
drive end of the cables.
2. Attach screw-on lugs to the drive.
70 2/0
Burndy YAL26T38 MY29-3 2
Ilsco CRA-2/0 IDT-12 1
Ilsco CCL-2/0-38 MT-25 1
Thomas & Betts 54110 TBM-8 3
95
3/0
Burndy YAL27T38 MY29-3 2
Ilsco CRA-3/0 IDT-12 1
Ilsco CCL-3/0-38 MT-25 1
Thomas & Betts 54111 TBM-8 3
95
3/0
Burndy YA28R4 MY29-3 2
Ilsco CRA-4/0 IDT-12 1
Ilsco CCL-4/0-38 MT-25 2
Thomas & Betts 54112 TBM-8 4
Wire size
Manufacturer Ring lug
Crimping
tool
No. of
crimps
mm
2
kcmil/
AWG
X60001
X60003
1
2