Parameters 273
36.09 Reset loggers Resets the peak value logger and/or amplitude logger 2.
(Amplitude logger 1 cannot be reset.)
Done
Done Reset completed or not requested (normal operation). 0
All Reset both the peak value logger and amplitude logger 2. 1
PVL Reset the peak value logger. 2
AL2 Reset amplitude logger 2. 3
36.10 PVL peak value Peak value recorded by the peak value logger. 0.00
-32768.00…
32767.00
Peak value. 1 = 1
36.11 PVL peak date The date on which the peak value was recorded. 01.01.1980
- Peak occurrence date. -
36.12 PVL peak time The time at which the peak value was recorded. 00:00:01
- Peak occurrence time. -
36.13 PVL current at peak Motor current at the moment the peak value was recorded. 0.00 A
-32768.00…
32767.00 A
Motor current at peak. 1 = 1 A
36.14 PVL DC voltage at
peak
Voltage in the intermediate DC circuit of the drive at the
moment the peak value was recorded.
0.00 V
0.00…2000.00 V DC voltage at peak. 10 = 1 V
36.15 PVL speed at peak Motor speed at the moment the peak value was recorded. 0.00 rpm
-30000.00…
30000.00 rpm
Motor speed at peak. See par.
46.01
36.16 PVL reset date The date on which the peak value logger was last reset. 01.01.1980
- Last reset date of the peak value logger. -
36.17 PVL reset time The time at which the peak value logger was last reset. 00:00:01
- Last reset time of the peak value logger. -
36.20 AL1 0 to 10% Percentage of samples recorded by amplitude logger 1 that
fall between 0 and 10%. 100% corresponds to the I
max
value
given in the ratings table in chapter Technical data in the
Hardware manual.
0.00%
0.00…100.00% Amplitude logger 1 samples between 0 and 10%. 1 = 1%
36.21 AL1 10 to 20% Percentage of samples recorded by amplitude logger 1 that
fall between 10 and 20%.
0.00%
0.00…100.00% Amplitude logger 1 samples between 10 and 20%. 1 = 1%
36.22 AL1 20 to 30% Percentage of samples recorded by amplitude logger 1 that
fall between 20 and 30%.
0.00%
0.00…100.00% Amplitude logger 1 samples between 20 and 30%. 1 = 1%
36.23 AL1 30 to 40% Percentage of samples recorded by amplitude logger 1 that
fall between 30 and 40%.
0.00%
0.00…100.00% Amplitude logger 1 samples between 30 and 40%. 1 = 1%
36.24 AL1 40 to 50% Percentage of samples recorded by amplitude logger 1 that
fall between 40 and 50%.
0.00%
0.00…100.00% Amplitude logger 1 samples between 40 and 50%. 1 = 1%
No. Name/Value Description Def/FbEq16
ACS580 FW.book Page 273 Wednesday, September 21, 2016 9:48 PM