Maintenance
122
Replacing the additional fan in the incoming cubicle (frames R7i+R7i and R8i+R8i)
WARNING! Follow the instructions in chapter Safety instructions. Ignoring the
instructions can cause physical injury or death, or damage to the equipment.
1. Disconnect the drive from the power line.
2. Open the incoming cubicle door.
3. Remove the four mounting screws of the fan.
4. Disconnect the fan power cable.
5. Pull out the fan.
6. Install new fan in reverse order.