Technical data
153
Losses, cooling data and noise
ACS800-17LC-1350-5 2003 1900 644 1950
ACS800-17LC-2000-5 2003 3100 644 3000
ACS800-17LC-2640-5 2003 3200 644 3350
ACS800-17LC-3930-5 2003 5000 644 4950
U
N
= 690 V
ACS800-17LC-0130-7 2003 1200 644 950
ACS800-17LC-0170-7 2003 1200 644 950
ACS800-17LC-0210-7 2003 1200 644 950
ACS800-17LC-0280-7 2003 1200 644 1100
ACS800-17LC-0390-7 2003 1200 644 1100
ACS800-17LC-0470-7 2003 1200 644 1100
ACS800-17LC-0630-7 2003 1200 644 1100
ACS800-17LC-0950-7 2003 1900 644 1950
ACS800-17LC-1240-7 2003 1900 644 1950
ACS800-17LC-1840-7 2003 2400 644 2350
ACS800-17LC-2430-7 2003 3200 644 3350
ACS800-17LC-3620-7 2003 4200 644 4250
ACS800-17LC-4630-7 2003 6200 644 6150
ACS800-17LC-5300-7 2003 6500 644 6000
ACS800-17LC-5960-7 2003 7400 644 7500
Drive type Losses Cooling data Noise
P
loss
(total)
P
loss
(coolant)
P
loss
(air)
Coolant
quantity
Massflow Pressure loss
kW kW kW l l/min kPa dBA
U
N
= 400 V
ACS800-17LC-0110-3 5.1 5.0 0.1 10.3 41 100 59
ACS800-17LC-0140-3 7.1 7.0 0.1 10.3 41 100 59
ACS800-17LC-0170-3 6.7 6.6 0.1 10.3 41 100 59
ACS800-17LC-0200-3 7.7 7.5 0.1 10.3 41 100 59
ACS800-17LC-0260-3 12.4 12.2 0.2 10.3 41 100 59
ACS800-17LC-0350-3 14.6 14.3 0.3 10.3 41 100 59
ACS800-17LC-0430-3 17.4 17.1 0.3 10.3 41 100 59
ACS800-17LC-0580-3 22.1 21.7 0.4 11.1 41 100 59
ACS800-17LC-0870-3 33.3 32.6 0.7 16.6 79 100 62
ACS800-17LC-1130-3 43.2 42.3 0.9 16.6 79 100 62
ACS800-17LC-1680-3 64.4 63.1 1.3 26.1 116 100 64
ACS800-17LC-2220-3 84.5 82.8 1.7 29.9 152 100 65
ACS800-17LC-3300-3 125.3 122.8 2.5 44.6 226 100 67
U
N
= 500 V
ACS800-17LC-0120-5 4.8 4.7 0.1 10.3 41 100 59
ACS800-17LC-0170-5 6.5 6.4 0.1 10.3 41 100 59
Drive type Height Width Depth Weight
mm mm mm kg