370 Parameters
47.27 Data storage 7
int16
Data storage parameter 23. 0
-32768 … 32767 16-bit integer. 1 = 1
47.28 Data storage 8
int16
Data storage parameter 24. 0
-32768 … 32767 16-bit integer. 1 = 1
47.31 Data storage 1
real32 type
Defines the scaling of parameter 47.01 Data storage 1 real32
to and from 16-bit integer format. This scaling is used when
the data storage parameter is the target of received 16-bit
data (defined in parameter group 62 D2D and DDCS receive
data), or when the data storage parameter is the source of
transmitted 16-bit data (defined in parameter group 61 D2D
and DDCS transmit data).
The setting also defines the visible range of the storage
parameter.
Unscaled
Unscaled Data storage only. Range: -2147483.264 2147473.264. 0
Transparent Scaling: 1 = 1. Range: -32768 32767. 1
General Scaling: 1 = 100. Range: -327.68 327.67. 2
Torque The scaling is defined by parameter 46.03 Torq u e sc al ing .
Range: -1600.0 1600.0.
3
Speed The scaling is defined by parameter 46.01 Speed scaling.
Range: -30000.00 30000.00.
4
Frequency The scaling is defined by parameter 46.02 Frequency scaling.
Range: -500.00 500.00.
5
47.32 Data storage 2
real32 type
Defines the 16-bit scaling of parameter 47.02 Data storage 2
real32.
See parameter 47.31 Data storage 1 real32 type.
Unscaled
47.33 Data storage 3
real32 type
Defines the 16-bit scaling of parameter 47.03 Data storage 3
real32.
See parameter 47.31 Data storage 1 real32 type.
Unscaled
47.34 Data storage 4
real32 type
Defines the 16-bit scaling of parameter 47.04 Data storage 4
real32.
See parameter 47.31 Data storage 1 real32 type.
Unscaled
47.35 Data storage 5
real32 type
Defines the 16-bit scaling of parameter 47.05 Data storage 5
real32.
See parameter
47.31 Data storage 1 real32 type.
Unscaled
47.36 Data storage 6
real32 type
Defines the 16-bit scaling of parameter 47.06 Data storage 6
real32.
See parameter 47.31 Data storage 1 real32 type.
Unscaled
47.37 Data storage 7
real32 type
Defines the 16-bit scaling of parameter 47.07 Data storage 7
real32.
See parameter 47.31 Data storage 1 real32 type.
Unscaled
47.38 Data storage 8
real32 type
Defines the 16-bit scaling of parameter 47.08 Data storage 8
real32.
See parameter 47.31 Data storage 1 real32 type.
Unscaled
No. Name/Value Description Def/FbEq16