EasyManua.ls Logo

ABB ACS880-104

ABB ACS880-104
664 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Additional parameter data 517
DIO3/DIO4 (15.01 Module 2 type = FIO-01)
15.19 DIO3 function List 0…1 - 1 = 1
15.21 DIO3 output source Binary
src
--1 = 1
15.22 DIO3 ON delay Real 0.00 … 3000.00 s 100 = 1 s
15.23 DIO3 OFF delay Real 0.00 … 3000.00 s 100 = 1 s
15.24 DIO4 function List 0…1 - 1 = 1
15.26 DIO4 output source Binary
src
--1 = 1
15.27 DIO4 ON delay Real 0.00 … 3000.00 s 100 = 1 s
15.28 DIO4 OFF delay Real 0.00 … 3000.00 s 100 = 1 s
RO1/RO2 (15.01 Module 2 type = FIO-01 or FDIO-01)
15.31 RO status PB 0000h…FFFFh - 1 = 1
15.34 RO1 source Binary
src
--1 = 1
15.35 RO1 ON delay Real 0.00 … 3000.00 s 100 = 1 s
15.36 RO1 OFF delay Real 0.00 … 3000.00 s 100 = 1 s
15.37 RO2 source Binary
src
--1 = 1
15.38 RO2 ON delay Real 0.00 … 3000.00 s 100 = 1 s
15.39 RO2 OFF delay Real 0.00 … 3000.00 s 100 = 1 s
Common parameters for AIx (15.01 Module 2 type = FIO-11 or FAIO-01)
15.19 AI supervision function List 0…4 - 1 = 1
15.20 AI supervision selection PB 0000h…FFFFh - 1 = 1
15.21 AI tune List 0…6 (FIO-11)
0…4 (FAI O-01)
-1 = 1
15.22 AI force selection PB 00000000h…FFFFFFFFh - 1 = 1
AI1/AI2 (15.01 Module 2 type = FIO-11 or FAI O - 01 )
15.26 AI1 actual value Real -22.000 22.000 mA or V 1000 = 1 unit
15.27 AI1 scaled value Real -32768.000 … 32767.000 - 1000 = 1
15.28 AI1 force data Real -22.000 22.000 mA or V 1000 = 1 unit
15.29 AI1 HW switch position List --1 = 1
15.30 AI1 unit selection List --1 = 1
15.31 AI1 filter gain List 0…7 - 1 = 1
15.32 AI1 filter time Real 0.000 … 30.000 s 1000 = 1 s
15.33 AI1 min Real -22.000 22.000 mA or V 1000 = 1 mA
or V
15.34 AI1 max Real -22.000 22.000 mA or V 1000 = 1 mA
or V
15.35 AI1 scaled at AI1 min Real -32768.000 … 32767.000 - 1000 = 1
15.36 AI1 scaled at AI1 max Real -32768.000 … 32767.000 - 1000 = 1
15.41 AI2 actual value Real -22.000 22.000 mA or V 1000 = 1 unit
15.42 AI2 scaled value Real -32768.000 … 32767.000 - 1000 = 1
No. Name Type Range Unit FbEq32

Table of Contents

Other manuals for ABB ACS880-104