Refitting the tubular and tilt unit for CRB 1300-7/1.4
Use these procedures to refit the tubular and tilt unit for CRB 1300-7/1.4
Refitting the tilt unit
NoteAction
Screw: M4x12 12.9 Lafre
2C2B/FC6.9 (12 pcs)
Refit the tilt unit.1
Tightening torque: 4.5 Nm
xx2000001741
Refitting the tubular support
NoteAction
xx2000002523
For robots with protection class IP67 (option
3350-670)
1 Remove residual locking liquid and other
pollutants with cleaning agent Loctite 7063.
2 Apply flange sealing Loctite 574 on the
mounting surfaces of the CP/CS connector
and wipe clean if there is any overflowing
Loctite 574.
1
Screw: M6x20 12.9 Gleitmo
603+Geomet 500 (6 pcs)
Refit the tubular support.2
Tightening torque: 14 Nm
xx2000001740
Continues on next page
Product manual - CRB 1300 467
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.5.3 Replacing the tubular and tilt unit
Continued