NoteAction
xx2000001537
Snap loose and remove the male head of the
connectors from the connector plate.
3
Separating the cable package from the tubular
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx2000001748
Remove the first semicircular bracket that fixes
the cable package.
2
xx2000001749
Remove the second semicircular bracket from the
tubular.
3
Removing the process hub
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
Continues on next page
Product manual - CRB 1300 637
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.7.4 Replacing the axis-4 gearbox
Continued