Reconnecting the axis-4 motor connectors
NoteAction
xx2000001545
Insert the male header of the motor connectors
to the connector plate.
1
xx2000001544
Reconnect the connectors.
FB4
MP4
Tip
See the number markings on the connectors for
help to find the corresponding connector.
2
xx2000001543
Route and secure the cabling with a cable strap.
Note
The motor cablings have another strap fixed. Pay
attention to the location where the new strap to
be fixed, see the figure as a guidance.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Refit the connector plate.4
Tightening torque: 2.6 Nm
xx2000001542
Continues on next page