EasyManua.ls Logo

ABB IRB1410 - Calibration Movement Directions for All Axes

ABB IRB1410
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Calibration information
5.0.4 Calibration movement directions for all axes
118 3HAC026320-001 Revision: A
5.0.4 Calibration movement directions for all axes
Overview
When calibrating, the axis must consistently be run towards the calibration position in the
same direction, in order to avoid position errors caused by backlash in gears etc. Positive
directions are shown in the figure below.
This is normally handled by the robot calibration software.
Calibration movement directions, 6 axes
NOTE!
The figure shows an IRB 7600, but the positive direction is the same for all 6-axis robots,
except the positive direction of axis 3 for IRB 6400R which is in the opposite direction!
xx0200000089