MC96F6432S
ABOV Semiconductor Co., Ltd.
Figure 11.11 Input Capture Mode Operation for Timer 0
Figure 11.12 Express Timer Overflow in Capture Mode
T0CNT
Interrupt
Request
(FLAG10)
XX
H
Interrupt Interval Period = FF
H
+01
H
+FF
H
+01
H
+YY
H
+01
H
Ext. EINT10 PIN
Interrupt
Request
(T0IFR)
FF
H
FF
H
YY
H
00
H
00
H
00
H
00
H
00
H
T0CNT Value
Interrupt
Request
(FLAG10)
TIME
1
2
3
4
5
6
n-2
n-1
n
Interrupt Interval Period