117
MC96F6432S
ABOV Semiconductor Co., Ltd.
T0CR (Timer 0 Control Register): B2H
7
6
5
4
3
2
1
0
T0EN
T0MS1
T0MS0
T0CK2
T0CK1
T0CK0
T0CC
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Initial value: 00H
T0EN
Control Timer 0
0
Timer 0 disable
1
Timer 0 enable
T0MS[1:0]
Control Timer 0 Operation Mode
T0MS1
T0MS0
Description
0
0
Timer/counter mode
0
1
PWM mode
1
x
Capture mode
T0CK[2:0]
Select Timer 0 clock source. fx is a system clock frequency
T0CK2
T0CK1
T0CK0
Description
0
0
0
fx/2
0
0
1
fx/4
0
1
0
fx/8
0
1
1
fx/32
1
0
0
fx/128
1
0
1
fx/512
1
1
0
fx/2048
1
1
1
External Clock (EC0)
T0CC
Clear timer 0 Counter
0
No effect
1
Clear the Timer 0 counter (When write, automatically cleared 0 after being
cleared counter)
NOTE)
1. Match Interrupt is generated in Capture mode.
2. Refer to the external interrupt flag 1 register (EIFLAG1) for the T0 interrupt flags.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Abov MC96F6432S Series and is the answer not in the manual?

Abov MC96F6432S Series Specifications

General IconGeneral
BrandAbov
ModelMC96F6432S Series
CategoryMicrocontrollers
LanguageEnglish

Related product manuals