Page #126 background image
50 UK
Phone Line
Fault
Telephone line not available for more than 40 s
For the device, the telephone line is available
when the voltage on the a/b line > 3 V.
Line OK
Telephone line back in normal state
Remote Start
Remote access established
Remote Clear
Remote access ended
Time changed
System date and system time have been changed
Supply Low
The supply voltage has fallen below the preset lower
voltage limit
Supply OK
The supply voltage has again exceeded the preset lower
voltage limit. The supply voltage is again in the normal
range.
Auto Report
Automatic test call
Log Cleared
Event log was deleted
After a complete factory reset, the event log is
deleted.
No Ack Name
01
No acknowledgment of the message by contact 1
Contacts 210 analogously
The contact name is displayed as programmed.
“Name 01” is the factory setting.
Call Fail Name
01
Call to contact 1 failed
Contacts 210 analogously
The contact name is displayed as programmed.
“Name 01” is the factory setting.
GSM Signal
Low
The GSM signal has dropped below the preset value for
the low end of the GSM signal strength.
GSM Sig. OK
The GSM signal has again exceeded the preset value for
the low end of the GSM signal strength. The GSM signal is
present and is again in the normal range.
Call PSTN
Call being made over the analog telephone line
Call GSM
Call being made over the GSM network