14. Stop the engine and inspect for leaks.
15. Check the oil level. Add oil as needed to bring the level to the upper mark on the window.
2.12
MAINTENANCE
Engine Mounts
Inspect engine mounts for cracks or damage.
Engine Fastener Torque
Check engine fasteners and ensure they are tight
CVT Drying
NOTE: If operating the ATV through water, be sure to check the CVT and other components for water
ingestion. The ATV should be checked immediately.
There may be some instances when water is accidently ingested into the CVT system. Use the following instructions to dry it
out before operating. The drain plug is located on the bottom of the CVT cover.
1. Remove the drain plug located under the CVT
housing. Allow the water to drain. Reinstall the drain
plug.
2. Shift the transmission into neutral.
3. Start the engine. Apply varying throttle for 10-15
seconds to expel the moisture and air-dry the belt and
clutches. Do not hold the throttle wide open for more than
3 - 4 seconds.
4. Allow the engine RPM to settle to an idle speed.
5. Test for belt slippage. If the belt slips, repeat the process.