MAIN FEATURES OF THE UNIT
COMFORT AND ENERGY SAVING
The inverter technology allows these units to respond quickly to
load changes, which leads to less water temperature fluctuation
and better comfort.
ULTRA QUIET
The DC brushless axial fans are high efficiency and low
noise fans able to optimize the passage of air, this allows to
considerably reduce the operating noise of the units.
The QUIET function, programmable via the touch screen control
panel, guarantees ultra-quiet operation.
SELF-DIAGNOSIS FUNCTION
Units equipped with a self-diagnosis system capable of
providing high and complete protection.
RELIABILITY
Thanks to the careful design, the excellent materials used for
the construction, the HMG units guarantee excellent operating
reliability.
REMOTE ON AND OFF
The units can be switched on and off thanks to the control via
BMS.
BALANCED OPERATION
Possibility, in the units where there are more than one
compressor, of alternating operation to extend their useful life
and to reduce their maintenance to a minimum.
PUMP ROTATION FUNCTION
Two water pumps can work alternately, for a period of equal
duration, in order to extend their useful life and reduce the
frequency of maintenance.
ACCESSORIES
TCP
Touch screen control panel (mandatory accessory).
VMF-485LINK
Expansion to interface the unit with the VMF communication pro
-
tocol, making it possible to manage it from the VMF-E6 supervi-
sor.
IC-2P
Connector for using communication via ModBus or VMF-485LINK.
Mandatory accessory if combined with VMF-485LINK or for third-
party supervision systems.
VMF-E6
White recessed panel with 4.3-inch color touch screen display,
allows centralized command / control of a complete hydronic /
aeraulic system consisting of: fan coils (up to 64 fan coil zones
consisting of 1 master + maximum 5 slaves ), heat pumps (up to
4), MZC accessories (up to 5), radiant panel management (using
an adequate number of VMF-REB accessories, up to 64 radiant
panels associated with the fancoil zones and up to 32 radiant
panels associated with the zones served by MZC), complete man
-
agement of domestic hot water production, control of the RAS re-
sistance and / or of the boiler, management of digital I / O, control
of recuperators and VOC probes (up to 4).
TCP CONTROL PANEL
For information and details on the TCP control panel (manda-
tory accessory), refer to the dedicated documentation.
MATERIAL SUPPLIED
Description
Quantity
(no.)
HMG0350 HMG0600
1
Communication cable
between units L= 8 m
1 • •
2
Communication cable
between units and
TCP L= 2 m
1 • •
1. Communication cable to be used for connecting one
module to the next in case of installation according to
homogeneous modularity (only 1 mandatory TCP accessory
per system). For more information, refer to the paragraph
dedicated to the types of modularity available for these units.
2. USE OF ADDITIONAL COMMUNICATION CABLE BETWEEN
UNITS AND TCP
In case you need to check the unit on the machine (e.g.:
maintenance, start-up) a secondary communication cable is
available, standard supply with the unit.
NOTE: do not use two Control panels at the same time.
1 2
1
2
NOTA
Il pannello di controllo TCP dev'essere installato e in un
luogo in cui la temperatura sia compresa tra -20 °C e 70°C.
Per evitare danni, non deve mai essere installato
direttamente all'esterno senza protezione.