1003 1 1st tray [0 to 10 / 5 / 1 mm/step]
1003 4 By-pass feed [0 to 10 / 6 / 1 mm/step]
1007 Display By-pass
1007 1 Display By-pass Displays the by-pass paper width switch output.
1103*
Fusing Idling
This program decides the action of the Fusing Drive Release Mechanism. When you select
"1," the contact/release control is disabled and the drive power is always transmitted to
the fusing
unit. As a result, the machine takes a longer time to warm up the fusing unit. Use
SP 1103 1 if fusing quality is low even when the room temperature is not very low.
1103 1 Fusing Idling [0 = No / 1 = Yes]
1105*
Fusing Temperature Adjustment
Adjusts the target fusing temperature. "Center" indicates the center of the roller; "End"
indicates the front and rear ends.
1105 1 Warm Up-Center
[140 to 180 / 160 / 1°C/step]
1105 2 Warm Up-End
1105 3 Standby-Center [140 to 170 / 155 / 1°C/step]
1105 4 Standby-End [140 to 165 / 150 / 1°C/step]
1105 5 Copying-Center
[140 to 185 / 160 / 1°C/step]
1105 6 Copying-End
1105 7 Low Level 2-Center
[0 to 80 / 60 / 1°C/step]
1105 8 Low Level 2-End
1105 9 Thick-Center
[140 to 185 / 175 / 1°C/step]
1105 10 Thick-End
1105 11 Warm Up Low-Center
[140 to 180 / 170 / 1°C/step]
1105 12 Warm Up Low-End