181
Settings and Adjustments
Station programming
4
■ Option Relay Control Authentication Key
Sound Settings • Door Release: Select the Door Release
sounds to be played.
• Relay Control (start): Select the sound to
be played when Option Relay is activated.
• Relay Control (end): Select the sound to
be played when Option Relay is
deactivated.
• None
• Call Pattern 1
• Call Pattern 2
• Call Pattern 3
• Call Pattern 4
• Call Pattern 5
• Call Pattern 6
• Tremolo Sound
• Busy Response Tone
• On Hold
• Operation Sound
• Error
• Pre Tone 1
• Pre Tone 2
• Pre Tone 3
• Communication End
Pretone
• Call Queue Notification
• Waiting Reply Tone
• Select a sound that is
registered in
“Custom
Sound Registry
(→page 172)”.
Door Release:
Operation Sound
Relay Control (start):
None
Relay Control (end):
None
Important
• Configure the Authentication Key using 1 to 4 digits to release when using the IX-MV.
• Configure a different Authentication Key for each output terminal (the same key cannot be used.)
• Configure an Authentication Key that is different from the Authentication Key configured in "Option Relay Control
Authentication Key." If the setting is the same, multiple functions might operate.
Note
• The "Authentication Key" is displayed as "●●●●●" in the Settings screen.
Entry Description Settings Default values
Option Relay Control
Authentication Key
If "Option Relay Control (administrator setting)"
is set to "Enable" and "Speed Dials / Favorites" -
"TLS" is set to "Enable" on the requesting
station, configure the key used to decrypt
encrypted communication.
If this matches the "Option Relay Control Key"
of the station performing the operation, the
Relay Output can be controlled.
1 - 20 digits -
Note
• Only one Option Relay Control Authentication Key can be set for each station. It will be shared with multiple Relay Output.
• The "Option Relay Control Authentication Key" is displayed as "●●●●●" in the Settings screen.
Entry Description Settings Default values