Settings and Adjustments
Station programming
4
Function Settings
Door Release
Door Release Assignment
Entry Description Settings Default values
Contact Assignment Select which relay output will be used for door
release during call or monitoring.
Originating Station: Use
origination station relay
output for door release.
Destination Station: Use
destination station relay
output for door release.
Destination Station
Authentication Key When "Destination Station" is selected in
"Contact Assignment", set the Authentication
Key for door release.
Authentication Key must match with the
destination station's authentication key to allow
door release.
1 - 20 digits -
Note
The "Authentication Key" is displayed as "●●●●" in the Settings screen.
Configure the door release key using 1 to 4 digits, when releasing an electrical lock connected to IX-MV, IX-DA(-*), or IX-BA.