R28 Door Phone Administrator Guide
www.akuvox.com
63
Note
DoorNum in the HTTP command above refers to the relay number #1 to be
triggered for the door access.
Please refer to the following example:
http://192.168.35.127/fcgi/do?
action=OpenDoor&UserName=admin&Password=12345&DoorNum=1
14.10
Configure Exit Button for Door Unlock
When you need to open the door from inside using the Exit button installed by the door,
you can configure the door phone Input to trigger the relay for the door access on
web Intercom > Input interface.
Parameter Set-up:
Enabled: it is enabled by default.
Trigger Electrical Level: select the trigger electrical level options
between High and Low according to the actual operation on the exit button.
Action to Execute: select the method to carry out the action: FTP, Email, HTTP,
TFTP, Manager Dial.