System Management
7210 SAS M, T, X, R6 Basic System Configuration Guide Page 397
Syntax [no] alarm-output-severity {critical | major | none} (for 7210 SAS-M)
[no] alarm-output-severity {critical | major | minor | none} (for 7210 SAS-X and 7210 SAS-
T only)
Context config>system>alarm-contact-input
Description This command allows the user to relay alarms from the alarm-contact input to the alarm-contact
output by associating an appropriate alarm-contact output with the alarm-contact input. The system
generates or clears the alarm-contact output when it triggers or clears the alarm for the associated
alarm-contact input.
If multiple alarm-contact input pins share an alarm-contact output, the system generates the alarm-
contact output even if any one of the alarm-contact input is triggered and the system clears alarm-
contact output only when all the alarm-contact input pins are cleared.
The severity parameter configured by the user determines the appropriate alarm-contact output to be
used for generation and clearing the alarm.
Note: The system relays the alarm-contact input to the appropriate alarm-contact output only if the
alarm-contact output is available on the platform.
Default Major
Parameters criticalA critical alarm output is generated or cleared.
major — A major alarm output is generated or cleared.
minor — A minor alarm output is generated or cleared.
none — No alarm output is generated or cleared.
clear-alarm-msg
Syntax [no] clear-alarm-msg {alarm-msg-text}
Context config>system>alarm-contact-input alarm-contact-input-id
Description This command allows the user to configure a text message for use along with SNMP trap and Log
message that are sent when the system clears an alarm. The system generates a default message if the
message is not configured. The system does not generate a trap or log if no form of the command is
enabled.
Default None
Parameters alarm-msg-text — A printable character string, up to 160 characters in length.
description