System Management
7210 SAS M, T, X, R6 Basic System Configuration Guide Page 475
Sample Output
Sample output for 7210 SAS-M, SAS-T, and 7210 SAS-X devices:
*A:7210SAS>show>system# vwm-shelf
===========================================================================
Shelf Summary
===========================================================================
Shelf-ID   USB/   Admin       Oper       Number of
    OMC    State       State      Equipped slots
---------------------------------------------------------------------------
7       USB    UP      UP      2
===========================================================================
*A:7210SAS>show>system#
Sample output for 7210 SAS-T devices:
Slot-ID
Card identifier used to identify the card inserted into the slot #1 of the 
1830 device.
Provisioned Type
User provisioned card-type to identify the module inserted into the 
1830 device. 
Equipped Type
The card-type currently inserted into the slot on the 1830 device.
No of Slots
The number of slots available on the 1830 device.
Part Number
The 1830 VWM CWDM device part number. 
CLEI code
CLEI code of the 1830 device.
Unit Mnemonic 
The Mnemonic string used to identify the card.
Serial Number
The 1830 device serial number.
Manufacturing 
Date
The manufacturing date of the card.
Administrative 
state
The administrative state of the 1830 device. If the shelf or card is pro-
visioned and if no shutdown is executed, the this field displays UP, else 
it displays 'Down'.
Operational state
The operational state of the 1830 device. It is set to UP if the 7210 SAS 
device is able to communicate and retrieve information from the 1830 
device connected to it. It is set to Down otherwise.
Current Alarm 
state 
Displays if alarm is active or cleared.
Table 36: Show VWM-shelf Output Fields  (Continued)
Label Description