Root Commands
7210 SAS M, T, X, R6 Basic System Configuration Guide Page 85
repeat repeat — Configures how many times the command is repeated.
Default 10
Values 1 — 999
absolute — When the absolute keyword is specified, the absolute rate-per-second value for each
statistic is displayed.
rate — When the rate keyword is specified, the rate-per-second for each statistic is displayed instead
of the delta.
sdp
Syntax sdp {sdp-id | far-end ip-address} [interval seconds] [repeat repeat] [absolute | rate]
Context monitor>service>id service-id
Description This command monitors statistics for a SDP binding associated with this service.
Parameters sdp-id — Specify the SDP identifier.
Values 1 — 17407
absolute — When the absolute keyword is specified, the absolute rate-per-second value for each
statistic is displayed.
far-end ip-address — The system address of the far-end 7210 SAS for the SDP in dotted decimal
notation.
interval seconds — Configures the interval for each display in seconds.
Default 11 seconds
Values 11 — 60
rate — When the rate keyword is specified, the rate-per-second for each statistic is displayed instead
of the delta.
repeat repeat — Configures how many times the command is repeated.
Default 10
Values 1 — 999
Sample Output
A:ALA-12# monitor service id 100 sdp 10 repeat 3
===============================================================================
Monitor statistics for Service 100 SDP binding 10
===============================================================================
At time t = 0 sec (Base Statistics)
-------------------------------------------------------------------------------
I. Fwd. Pkts. : 0 I. Dro. Pkts. : 0
E. Fwd. Pkts. : 0 E. Fwd. Octets : 0
-------------------------------------------------------------------------------
At time t = 11 sec (Mode: Delta)
-------------------------------------------------------------------------------

Table of Contents

Other manuals for Alcatel-Lucent 7210 SAS M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 7210 SAS M and is the answer not in the manual?

Alcatel-Lucent 7210 SAS M Specifications

General IconGeneral
BrandAlcatel-Lucent
Model7210 SAS M
CategorySwitch
LanguageEnglish

Related product manuals