Rockwell Automation Publication 290E-UM001B-EN-P - June 2012 153
Bulletin 290E/291E/294E Programmable Parameters Chapter 4
AutoRstrtDelay
Sets time between restart attempts when
Parameter 84(Auto Rstrt Tries) is set to a
value other than zero.
Parameter Number 85
Related Parameter 84
Access Rule GET/SET
Data Type UINT
Group Advanced Config.
Units x.x secs
Minimum Value 0.0
Maximum Value 120.0
Default Value 1.0
BoostSelect
Sets the boost voltage (% of Parameter 28
[MotorNPVolts]) and redefines the Volts
per Hz curve.
See Table24 for details.
Parameter Number 86
Related Parameters 28, 29
Access Rule GET/SET
Data Type UINT
Group Advanced Config.
Units —
Minimum Value 1
Maximum Value 14
Default Value 8
Table 24 - Boost Select Options
Options Description
Custom V/Hz
Variable Torque
(Typical fan/pump curves)
1 30.0, VT
2 35.0, VT
3 40.0, VT
4 45.0, VT
5 0.0 no IR
Constant Torque
6 0.0
7 2.5, CT
8 5.0, CT (default)
9 7.5, CT
10 10.0, CT
11 12.5, CT
12 15.0, CT
13 17.5, CT
14 20.0, CT

Table of Contents