104 Rockwell Automation Publication 1783-UM007G-EN-P - February 2017
Chapter 4 Install Stratix 5410 Switches
Obtain these tools:
• Ring, spade, or flanged spade terminal (terminals should be insulated)
– Ring terminal (such as Tyco part number 2-34158-1 for
16…14 AWG or 2-34852-1 for 12…10 AWG wire)
– Spade terminal (such as Tyco part number 54367-2 for 16…14
AWG wire)
– Flanged spade terminal (such as Tyco part number 2-324165-1 for
16…14 AWG wire or 1-324581-1 for 12…10 AWG wire)
• Crimping tool, such as Thomas & Bett part number WT2000,
ERG-2001, or equivalent
• 6-gauge copper ground wire, such as Belden part number 9906 or
equivalent
• 12-AWG wire (minimum) for the low-voltage power-supply module
and 16-AWG (minimum) wire for the high-voltage power-supply
module
• For power source connections, use wires that are rated for at least 194°F
(90°C).
• UL- and CSA-rated style 1007 or 1569 twisted-pair copper wire, such as
Belden part number 9318
• Wire-stripping tools for stripping 6-, 10-, 12-, 14-, and 16-gauge wires.
• Number-2 Phillips screwdriver
• Flat-blade screwdriver
For simplified cabling, the automatic medium-dependent interface crossover
(auto-MDIX) feature is enabled by default on the switch. With auto-MDIX
enabled, the switch detects the required cable type for copper Ethernet
connections and configures the interfaces accordingly. Therefore, you can use
either a crossover or a straight-through cable for connections to a 10/100/1000
Ethernet, PoE/PoE+ switch port, regardless of the type of device on the other
end of the connection.