Initialization Menu
Display Mes-
sage Default Information Limits
Heat.Err.Det.Time 10 Minutes If Wait for Temperature has been enabled, Error 13 will appear in the
control's display if the water temperature doesn't increase by 5.4°F
[3°C] within the programmed amount of time.
10 - 20 Minutes
Max. Water Fill
Time
10 Minutes A diagnostic message is generated by the wash computer when the wa-
ter hasn't reached the programmed level in 10 Minutes. (Err 11).
NOTE: If 99 minutes has been selected, NO error message
will be generated at all, even if the heating time exceeds 99
minutes. The machine will only stop filling when the pro-
grammed water level has been reached.
5 - 99 Minutes
Overfill Detection 5 units A diagnostic message is generated by the wash computer when the wa-
ter has reached the programmed level + 5 units. (Err 12).
NOTE: It's strongly recommended that the heating power of
the steam installation has enough power to heat the bath
quickly. Otherwise the tub will be filled with extra water and
an error message will occur that the machine takes more
then 5 units extra water. This will also increase the water,
energy and detergent supply consumption.
To solve the problem in another way, reduce the programmed target
water level so that less energy is needed to heat up the bath and with
the extra water of the condensed steam you will wash with a normal
amount of water.
3 - 25 units
Table 8 continues...
Initializing the Machine
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
29 Part No. D1676ENR11