12. Timing Chart (2-axis Type)
12-16
(7) Sample Hold 1 Mode “Force Measure Mode :
SH1(1)”
When 0=Setup parameter of the function menu is set as follows:
1 Force Measure Mode setting: SH1(1)
20ms min.
(*1)18ms
2ms
20ms max.
GOOD output(*2)
FINISH output(*2)
NG output(*2)
ST-FORCE2 input
Before Weld Force measurement
Force change 2
Before Weld Force measurement position
20ms min.
Force change 1
ST-FORCE1 input
*1 The output time of Before Weld Time varies depending on settings of Force
Sampling and Force Average.
*2 The output time can be selected with Output Select Time.