MU-100A
11. Timing Chart (1-axis Type)
11-12
(7) Sample Hold 1 Mode “Force Measure Mode :
SH1(1)”
When 0=Setup parameter of the function menu is set as follows:
1 Force Measure Mode setting: SH1(1)
GOOD output(*2)
FINISH output(*2)
NG output(*2)
ST-FORCE1 input
Before Weld Force measurement
Force change
Before Weld Force measurement position
20ms min.
(*1)15ms
2ms
*1 The output time of Before Weld Time varies depending on settings of Force
Sampling and Force Average.
*2 The output time can be selected with Output Select Time.