CHAPTER 5: SETUP SOFTWARE
UB25 LINEAR DC RESISTANCE WELDING CONTROL
5-22 990-665
Defaults for Setup Menu 2
SYSTEM PARAMETER DEFAULT SETTING
Display Contrast 080%
Buzzer Loudness 030%
End of Cycle Buzzer OFF
Update Graph After Weld ON
Buzzer On Weld Stop OFF
Defaults for Setup Menu 3
SYSTEM PARAMETER DEFAULT SETTING
Do Test Weld ALWAYS
Ignore First/Last 0.2 ms
Defaults for Waveform Check and Weld Fire Lockout
SYSTEM PARAMETER DEFAULT SETTING
Waveform Check ON
Stability Check % Limit 07 % 0 / 0
Stability Check Delay 2.0 ms
Energy Capacity % Limit: 05 % 0 / 0
Weld Fire Lockout Charge 90 %
Defaults for Communication Menu
SYSTEM PARAMETER DEFAULT SETTING
Communication Role CLIENT
RS-485 ID Number 01
Baud Rate 9600
Defaults for Chain Schedules Menu
SYSTEM PARAMETER DEFAULT SETTING
Chain Schedules OFF