Install lter and tighten properly with hand – as per lter •
manufacturer’s data (by 2/3 of revolution once lter is seat-
ed properly).
Disconnect water separator sensor connector, and pro-•
ceed the same like in previous text, connect sensor once
replaced.
Note:
Small amount of air that gets into the system during lter re-
placement will automatically deaerate if the replacement pro-
cedure described has been adhered to. Unless lters are lled
with fuel, deaerate the system according to Section called “Fuel
lter water separator”.
Use original lters required, refer to
Spare Parts Catalogue.
Do NOT tighten lters using force, the
thread and gasket may get damaged.
NEVER smoke when at work, replace
in well-ventilated rooms with no re
hazard.
Collect fuel owing out!
Store spent lters in separate containers
and hand them over for their disposal.