129AP 240
MAINTENANCE MANUAL
After 2,000 hours of operation (after 2 years)
3.6.28. Check, adjust valve clearance
Please, contact your regional CUMMINS representatives, •
refer to “Engine Operation And Maintenance Manual” (sup-
plied with the Machine), or your dealer.
3.6.29. How to exchange oil in rear axle
Clean and remove drain plugs (1), lling plugs (2) in both •
housings. With oil drained, install plugs (1) and pour 5,2 l
(1,4 gal US) amount through the holes into each housing as
per Section 3.2.6., close with plugs. Oil may ow out slightly
from holes (2).
Observe re precautions!
Use recommended oils only, as per
Section. 3.2.6.
Drain oil when operation has ended after
cooling down to 50 °C, or while driving
the Machine, wait until oil warms up.
Exchange oil rst after 250 hours of op-
eration of new Machine or after Major
Overhaul.
Beware of burn hazard when draining
hot oil.
Drain oil into collection vessel of 6 l (1.6
gal US) capacity.
Spent oil is ecological waste – hand over
for disposal.

Table of Contents