125AP 240
MAINTENANCE MANUAL
3.6.25. How to exchange CLARK gearbox oil
Remove plug, drain oil to a prepared vessel of 21,5 l (5,7 gal •
US) and at the same time replace lter as per Section named
“How to Replace Filter.
Open the cover underneath control panel.•
Pour the amount of 21,5 l (5,7 gal US) through a hole after •
having pulled out check dipstick, up to FULL mark. Start the
engine and while idling, check oil level to conrm it reaches
up to ADD mark. With oil warmed up to 82÷93 °C, please
check and ll up to FULL if required.
Drain oil when operation has ended af-
ter cooling down to 50 °C, or while driv-
ing you wait until oil warms up.
Beware of burn hazard when draining
hot oil .
Observe re precautions!
Use recommended oils according to
Section 3.2.5.
Drain oil into collection vessels.
Spent oil is ecological waste – hand over
for disposal.