127AP 240
MAINTENANCE MANUAL
Drain oil.•
Observe re precautions!
Use recommended oils according to
Section 3.2.6.
Drain oil into collection vessels.
Spent oil is ecological waste – hand over
for disposal.
Use hole (1) to pour 6 l (1.58 gal US) of oil. Check oil level in •
hole (2) (oil must pour out slightly). Tighten inspection plug
(2) with 80÷90 Nm (59÷66 lb ft) torque. Tighten ller plug (1)
with 70÷80 Nm (52÷59 lb ft) torque.