70 AP 240
2.7. Machine Control and Usage
For the maximum permissible slope gra-
dient when driving uphill and across the
slope gradient, see gures.
The values given are lower depending
on adhesive conditions and the machine
instantaneous weight!
Unless the engine cooling liquid temper-
ature reaches min 60 °C, do not load the
engine at full capacity!
Never use 3rd gear to start moving!
Never reverse with 2nd and 3rd gear!
During speed reduction, change in time
to a lower gear! You can shift under load
(Power shift).
Use dierential interlock only when re-
covering the Machine! Switch OFF the in-
terlock once heavy conditions are over-
come - danger of damage to dierential
or tires.
When oil temperature in gearbox rises
over 120 °C, stop the work, stop driving
and cool gearbox oil down to optimal 80-
100 °C in situ at increased engine speed
of 1500 rpm. If oil heats up to 120 °C
frequently, change the driving manner
- shift gears more frequently, clean oil
cooler!
Never use parking brake for normal
brake application.
! CAUTION !
When you select direction of running via controller,
and after braking o the Machine will start to move
slowly even with the engine idling.
While driving, keep the engine at rather high rpm
to achieve better controllability of steering the
Machine.