Firmware Pages and Descriptions
115
Modero VG Series Touch Panels - Instruction Manual
NOTE: The term "quality" (in the context of a battery), refers to the current capacity relative to the batteries’ rated capacity. For
example, after constant use, a battery may be operating at 75% of its rated capacity even though it might be fully charged. In this
case, the battery could be incorrectly reporting its’ information back to the battery base and then consequently relating this
information back to the Battery Base page. A battery can be recalibrated using an optional NXT-CHG (battery charger).
Battery Base Page Elements (Cont.)
Battery Status fields: This section provides the ability to monitor the current battery charge levels and charge qualities:
•The Combined Charge Status bargraph indicates the combined power charge available from both
internal battery connection slots (bargraph range = 0 - 100).
•The Battery One Charge Status bargraph indicates the power charge available on the Slot 1 internal
battery connection (bargraph range = 0 - 100).
•The Battery One Quality bargraph indicates the physical capacity (quality) of the battery. Quality is the
percentage of actual capacity vs. its rated capacity.
For optimal performance, a battery should be replaced when the quality rating drops below 80%.
•The Battery Two Charge Status bargraph indicates the power charge available on the Slot 2 internal
battery connection (range = 0 - 100).
•The Battery Two Quality bargraph indicates the physical capacity (quality) of the battery. Quality is the
percentage of actual capacity vs. its rated capacity.
•The Base Version field indicates the firmware version being used by the NXA-BASE/B Battery Base
connected to the NXT Modero panel.
•The Battery Level Port field indicates the port being used to report the combined charge status level back
to the NetLinx Master on (set in TPD4).
• The Battery Level field indicates the level being used to report the combined charge status level back to
the NetLinx Master on (set in TPD4).
Battery Power Brightness
Limit:
The DISABLE/DISABLED button acts as a power save feature with two available choices:
Disable - activates the brightness limit set on the Modero panel and is used
to conserve battery power. Activating this feature causes the panel to function at 80% of full brightness
and overrides the Panel Brightness value set on the Setup page. This extends the battery usage time.
Disabled - (illuminated when selected) deactivates this power save feature and makes the panel use the
specified Panel Brightness level set on the Setup page.