Firmware Pages and Descriptions
123
Modero VG Series Touch Panels - Instruction Manual
Refer to the Using G4 Web Control to Interact with a G4 Panel section on page 88 for more detailed instructions on how to use the
G4 Web Control Settings page with the new web-based NetLinx Security application.
Other Settings Slide-Out Menu
Pressing the Other Settings button causes an option men to slide outwards from the Protected Setup buttons (FIG. 122). This
option menu contains buttons to access the Cache Settings and Password Settings pages. Select any button to open its page.
G4 Web Control Page Elements
Back: Saves the changes and returns you to the previously active touch panel page.
Connection Status icon: This visual display of the connection status allows the user to have a current visual update of the panel’s
connection status regardless of what page is currently active.
A Lock only appears on the icon if the panel has established a connection with a currently secured
target Master (requiring a username and password).
G4 Web Control Settings: Sets the IP communication values for the touch panel and contains:
Enable/Enabled The Enable/Enabled button allows you to toggle between the two G4 activation settings:
- Enable - deactivates the G4 Web Control feature on the panel.
- Enabled - activates the G4 Web Control feature on the panel and allows an external PC running a VNC
client to access the panel (after the remaining f ields are configured).
Network Interface Select Displays the detected method of communication to the web:
Wired is used when a direct Ethernet connection is being used for communication to the web. This is a
default setting if no wireless interface card is detected by the panel.
Wireless is used when a wireless card is detected within the internal card slot. This method provides an
indirect communication to the web via a pre-configured Wireless Access Point.
Web Control Name Allows you to enter a unique alpha-numeric string that is used as the display name of the panel within the
Manage WebControl Connections window of the new NetLinx Security browser window.
This Web Control tab displays a G4 icon alongside the link to the Web Control Name given to this panel
(FIG. 121).
Web Control Password Allows you to enter the G4 Authentication session password associated for VNC web access of this panel.
Web Control Port Allows you to enter the port value that the VNC Web Server runs on.
Default value is 5900.
Maximum Number of
Connections
This read-only field displays the maximum number of users that can be simultaneously connected to the
target panel via the web.
•Default value is 1.
Current Connection Count This read-only field displays the current number of users connected to the target panel via the web. This
value cannot exceed the Maximum number f ield.
G4 Web Control Timeout: Sets the length of time (in minutes) the panel can remain idle (no cursor movements) before the session
is closed and the user is disconnected.
Minimum value = 0 minutes (panel never times-out)
Maximum value = 240 minutes (panel times-out after 240 minutes/4hours)
FIG. 121 Sample relationship between G4 Web Control and Mange WebControl Connections window
FIG. 122 Other Settings slide-out menu