EasyManua.ls Logo

AMX NXD-1700VG - Setting up a Modero Panel to Receive and Display a Stream; Step 1: Obtaining the IP Address of the Target Panel; Step 2: Configuring the MAX-CSE for Communication

AMX NXD-1700VG
187 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Displaying Stream Content
134
Modero VG Series Touch Panels - Instruction Manual
by default, cause the target Modero panel to look for the incoming audio portion of the stream on the same port as the
video (port 5000).
Obtain the IP Address being used by the target Modero panel by locating the IP Address field on the firmware’s System
Settings page.
Determine what is the available data rate for the network on which the encoder currently resides. This information will
determine what encoder profile can be used on the outgoing media content. If the network can only handle a throughput of
4 Mbps from the encoder, it is recommended that you use something less than or equal to the High Quality encoder profile.
Setting up a Modero Panel to Receive and Display a Stream
The MAX-CSE must first be prepared to stream to the target Modero panel prior to creating the necessary TPDesign4 panel pages
(later be uploaded to the panel).
Step 1: Obtaining the IP Address of the target panel
1. Press the grey Front Setup Access button for 3 seconds to open the Setup page (FIG. 130).
2. Press the Protected Setup button (located on the lower-left of the panel page) to open the Protected Setup page and display
an on-screen keypad.
3. Enter 1988 into the Keypad’s password field and press Done when finished.
4. Press the System Settings button (located on the Protected Setup page) to open the System Settings page and obtain the IP
information from the IP Address field (FIG. 131).
Step 2: Conf iguring the MAX-CSE for communication
1. Complete the procedures outlined within the Configuring the MAX Communication Parameters section of the MAX-CSE
Instruction Manual to establish an active connection to the source MAX-CSE.
2. Confirm the MAX-CSE is properly configured to use the newly established Static IP Address by launching your browser and
entering the MAX’s new Static IP Address into the browsers Address field.
3. Press the Enter key on your keyboard to initiate the communication process and launch the initial on-screen Enter Network
Password security dialog.
4. Enter the words administrator and password (if using the default login profile) into the corresponding User Name/Password
fields. This is the factory default security login information.
FIG. 130
Setup page
FIG. 131 System Settings page
Connection Status
Red Connection Status icon -
Green Connection Status icon -
indicates no connection to a Master
indicates communication to a Master
Modero
IP Address
information

Table of Contents

Other manuals for AMX NXD-1700VG

Related product manuals