Installation Procedures: 12" and 15" Panels
47
Modero VG Series Touch Panels - Instruction Manual
8. Insert and secure the twelve #6-32 securing screws into their pre-drilled holes along the edges of the NXD unit (FIG. 34). This
step secures the NXD unit to the rim of the rear plastic cover.
9. Align a VESA mount connector (purchased separately) to the four #8-32 screw holes on the back of the rear plastic cover
(FIG. 34).
10. Insert the four provided #8-32 screws through the VESA mount’s four holes and then into the pre-drilled holes on the rear
plastic cover.
NOTE: When installing a VESA mount to the rear plastic cover, use only the AMX provided #8-32 screws.
11. Secure the four #8-32 screws to the rear plastic cover with a grounded Phillips-head screwdriver to secure the VESA mount to
the rear of the panel.
Refer to your particular VESA mount manufacturers installation procedures for further surface mounting procedures.
Pre-wall Installation of the Conduit Boxes
Wall Mount panels (NXDs) are contained within a metallic outer housing (back box). This back box is not removed when installing
the NXD into a conduit box (CB-TP15 or CB-TP12). The back box is only removed to either gain access for the replacement of the
Memory/Compact Flash or upgrade the unit with an MB-TP Universal VESA Mounting Kit.
NOTE: INSTALLER: LEAVE A GAP BETWEEN THE STUD AND CONDUIT BOX TO ACCOMMODATE THE DRYWALL SHEETROCK. This gap
allows the installation of the drywall/sheetrock after the conduit box has been installed.
The most important thing to remember when mounting this conduit box is that the mounting tabs must be mounted flush against
the outside of the sheetrock.
The CB-TP12 and CB-TP15 conduit wallboxes are optional metallic boxes that are secured onto stud beams prior to the installation
of a solid surface. Installation procedures and configurations can vary. This section describes the installation procedures for the
most common installation scenario.
1. Fasten the CB-TP15 or CB-TP12 to a stud through the stud fastening holes, located on the inside of the conduit box (FIG. 38),
by using either nails or screws.
FIG. 37
Installation of grommet into the rear plastic enclosure
FIG. 38 Screw locations for conduit box attachment in a pre-wall installation
Rear plastic cover (rear view)
Rim of the strain relief grommet
should lie flush against enclosure
CLIP FACING UP
VESA mount connection location
(USE ONLY AMX PROVIDED #8-32 screws)
Drywall/
Stud
Knockouts should be located on the left-side of the
CB-TP Conduit Wallbox
conduit box, alongside the connectors
Stud fastening holes
Use the four #4-40
Mounting Screws to
secure the NXD to the
conduit box at these
sheetrock
Mounting tabs for NXD panel should
locations
be flush with the outside of the sheetrock