Panel Calibration
72
 Modero VG Series Touch Panels - Instruction Manual
Panel Calibration
Overview
This section outlines the steps for calibrating the touch panel. It is recommended that you calibrate the panel before its initial use 
and after completing a f irmware download.
Modero panels are factory setup with specific demo touch panel pages. The first splash screen that appears indicates the panel is 
receiving power, beginning to load firmware, and preparing to display the default touch panel pages. When the panel is ready, the 
AMX Splash Screen is replaced by the Initial Panel Page (FIG. 65).       
Calibrating the Modero Panel
1. Press and hold the grey Front Setup Access button (FIG. 66) for 6 seconds (passing-over the Setup page) to access the 
Calibrate page (FIG. 67). The panel should first be calibrated properly. 
2. Press the crosshairs (on the Calibrate page) to set the calibration points on the LCD (FIG. 67).  
FIG. 65  
AMX splash screen and Initial Panel Page
FIG. 66  Location of grey Front Setup Access button
FIG. 67  Touch Panel Calibration Screens
AMX Splash Screen
(appears during power-up)
Initial Panel Page
(AMX Logo Page)
Front Setup Access button
3 second press/hold: Accesses the Setup page
6 second press/hold: Accesses the Calibration page
Single press puts the panel to sleep
The request to touch the crosshairs
is the first on-screen message 
Calibration successful is the second
on-screen message that appears
On-screen crosshairs used for
calibration of the touch device
after the calibration process is 
completed