Installation Procedures: 17" Panels
65
Modero VG Series Touch Panels - Instruction Manual
3. Remove any screws/nails from the drywall, along the notched beam, before beginning the cutout process.
4. Cut out the surface for the NXD-1700VG Wall Mount using the dimensions shown in FIG. 58. Be sure to cut out the four
notches along the top and bottom areas to accommodate the four drywall expansion clips (provided).
5. Remove the magnetic faceplate/bezel (A in FIG. 59) from the main NXD unit (B in FIG. 59) by gripping the faceplate and pulling
with gentle outward force.
FIG. 58
NXD-1700VG Wall Mount panel dimensions using expansion clips
FIG. 59 Wall Mount panel (NXD) installation using expansion clips
*
*
* Top notches are
not symmetrical
Left Side
Right Side
Connectors
B - Main NXD unit consists of
Install the 4 drywall clip sets
the LCD panel and back box housing
Four notches are required if the unit is installed in
A - Faceplate (bezel)
Notching of one or more
stud beams may be
required if the unit is not
framed into the wall.
13.554"
(34.43 cm)
Mounting Tab
drywall using the 4 provided drywall expansion clips
(included) into these holes