Configuring Communication
89
Modero VG Series Touch Panels - Instruction Manual
6. Press the Enable/Enabled button until it toggles to Enabled (light blue color).
7. The Network Interface Select field is read-only and displays the method of communication to the web. Verify you have
selected the proper interface connection as this f ield does not auto-detect the connection type being used (see below).
Wired is used when a direct Ethernet connection is being used for communication to the web. This is the default setting if
either no wireless interface card is detected or if both an Ethernet and wireless card connection is detected by the panel.
Wireless is used when a wireless card is detected within the internal card slot. This method provides an indirect
communication to the web via a pre-configured Wireless Access Point.
8. Press the Web Control Name field to open the Web Name keyboard.
9. From the Web Name keyboard, enter a unique alpha-numeric string to identify this panel. This information is used by the
NetLinx Security Web Server to display on-screen links to the panel. The on-screen links use the IP Address of the panel and not
the name for communication (FIG. 86).
10. Press Done after you are finished assigning the alpha-numeric string for the Web Control name.
11. Press the Web Control Password field to open the Web Password keyboard.
12. From the Web Password keyboard, enter a unique alpha-numeric string to be assigned as the G4 Authentication session
password associated with VNC web access of this panel.
13. Press Done after you are finished assigning the alpha-numeric string for the Web Control password.
14. Press the Web Control Port field to open the Web Port Number keypad.
15. Within the keypad, enter a unique numeric value to be assigned to the port the VNC Web Server is running on. The default
value is 5900.
16. Press Done when you are finished entering the value. The remaining fields within the G4 Web Control Settings section of this
page are read-only and cannot be altered.
17. Press the Up/Down arrows on either sides of the G4 Web Control Timeout field to increase or decrease the amount of time the
panel can remain idle (no cursor movements) before the session is closed and the user is disconnected.
18. Press the Back button to open the Protected Setup page.
19. Press the on-screen Reboot button to save any changes and restart the panel.
NOTE: Verify your NetLinx Masters IP Address and System Number have been properly entered into the Master Connection section of
the System Settings page.
FIG. 85
G4 Web Control page
FIG. 86 Sample relationship between G4 Web Control and Mange WebControl Connections window