EasyManuals Logo

Anritsu Spectrum Master MS2720T User Manual

Anritsu Spectrum Master MS2720T
Go to English
1035 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #397 background imageLoading...
Page #397 background image
3-8 Interference Mapping Interference Analyzer (Option 25)
3-18 PN: 10580-00349 Rev. H Spectrum Analyzer MG
6. Save the Mapping Information.
Refer to “Save the Mapping Information” on page 3-19.
3 Current readings from the MA2700A.
Compass: Before GPS lock, the compass displays a light gray M indicating
magnetic north (no declination adjustment). With GPS lock, a declination
adjustment is automatically applied based on location and the compass changes to
display a light gray T indicating true north. The Arrow indicates the direction the
MA2700A is pointing.
Power level: Displays the power level at the Anritsu instrument’s receiver.
Bearing: Direction the MA2700A is pointing (shown in red).
Pitch (vertical level): Indicates the front-to-back orientation.
Roll (horizontal level): Indicates the side-to-side orientation.
4 Current Anritsu instrument settings.
5 GPS lock icon.
6 Current position.
7 Status Icons (left to right). Refer to Figure 6-12 on page 6-18.
MA2700A USB connection.
USB memory stick available.
Map auto-centering mode.
8 Zoom level indication (when using .azm maps). Top is maximum zoomed in position.
Bottom is maximum zoomed out position. Refer to “Pan & Zoom Menu” on page 6-17.
9 Current tile location in base map (when using .azm maps). Move the current tile location
around the base map using the arrow keys on the Anritsu analyzer.
Note: Panning is not functional when the instrument displayed map is at the maximum
zoomed out position.
10 Refer to “Interference Mapping Menu” on page 3-66.
11 Plus sign indicates current position.
12 Previous saved (trigger pull) locations and bearings. Existing bearings can be deleted.
Refer to “Bearing Lines Menu” on page 3-67.
13 Approximate location of the interfering signal.
Figure 3-10. Interference Mapping Overview (2 of 2)
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com

Table of Contents

Other manuals for Anritsu Spectrum Master MS2720T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Anritsu Spectrum Master MS2720T and is the answer not in the manual?

Anritsu Spectrum Master MS2720T Specifications

General IconGeneral
BrandAnritsu
ModelSpectrum Master MS2720T
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals