EasyManua.ls Logo

Areca ARC-1222 - RAID Set Event; Hardware Monitor Event

Areca ARC-1222
167 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
147
APPENDIX
C. RAID Set Event
Event Level Meaning Action
Create RaidSet Warning New RAID set created
Delete RaidSet Warning Raidset deleted
Expand RaidSet Warning Raidset expanded
Rebuild RaidSet Warning Raidset rebuilding
RaidSet
Degraded
Urgent Raidset degraded Replace HDD
D. Hardware Monitor Event
Event Level Meaning Action
DRAM 1-Bit ECC Urgent DRAM 1-Bit ECC error Check DRAM
DRAM Fatal
Error
Urgent DRAM fatal error
encountered
Check the DRAM module and
replace with new one if required.
Controller Over
Temperature
Urgent Abnormally high
temperature detected
on controller (over 60
degree)
Check air ow and cooling fan of
the enclosure, and contact us.
Hdd Over
Temperature
Urgent Abnormally high
temperature detected
on Hdd (over 55
degree)
Check air ow and cooling fan of
theenclosure.
Fan Failed Urgent Cooling Fan # failure
or speed below
1700RPM
Check cooling fan of the
enclosure and replace with a new
one if required.
Controller
Temp.
Recovered
Serious Controller
temperature back
tonormal level
Hdd Temp.
Recovered
Raid Powered
On
Warning RAID power on
Test Event Urgent Test event
Power On With
Battery Backup
Warning RAID power on with
battery backuped
Incomplete
RAID
Discovered
Serious Some RAID set
member disks
missing before power
on
Check disk information to nd out
which channel missing.
HTTP Log In Serious a HTTP login detected

Table of Contents

Related product manuals