BIOS CONFIGURATION
46
• Migrating
Migration occurs when a disk is added to a RAID set. Migrating
state is displayed in the RAID state area of “The Raid Set
Information” screen when a disk is being added to a RAID set.
Migrating state is also displayed in the associated volume state
area of the “Volume Set Information” which belongs this RAID
set.
3.7.2.4 Activate Incomplete Raid Set
I/O Port Addr : 28000000h, F2(Tab): Select Controller, F10: Reboot System
ArrowKey Or AZ:Move Cursor, Enter: Select, ESC: Escape, L:Line Draw, X: Redraw
Areca Technology Corporation RAID Controller
Main Menu
Quick Volume/Raid Setup
Raid Set Function
Volume Set Function
Physical Drives
Raid System Function
Ethernet Conguration
View System Events
Clear Event Buffer
Hardware Monitor
System information
Raid Set Function
Raid Set Function
Create Raid Set
Delete Raid Set
Expand Raid Set
Activate Raid Set
Create Hot Spare
Delete Hot Spare
Raid Set Information
Activate Raid Set
Select Raid Set To Activate
Raid Set # 00
I/O Port Addr : 28000000h, F2(Tab): Select Controller, F10: Reboot System
ArrowKey Or AZ:Move Cursor, Enter: Select, ESC: Escape, L:Line Draw, X: Redraw
Areca Technology Corporation RAID Controller
Main Menu
Quick Volume/Raid Setup
Raid Set Function
Volume Set Function
Physical Drives
Raid System Function
Ethernet Conguration
View System Events
Clear Event Buffer
Hardware Monitor
System information
Raid Set Function
Raid Set Function
Create Raid Set
Delete Raid Set
Expand Raid Set
Activate Raid Set
Create Hot Spare
Delete Hot Spare
Raid Set Information
Raid Set Iformation
The Raid Set Information
Raid Set Name : Raid Set # 00
Member Disks : 2
Raid State : Migrating
Total Capacity : 800.0GB
Free Capacity : 800.0GB
Min Member Disk Size : 400.0GB
Member Disk Channels : .E1S1.E1S2.
The following screen is used to activate the RAID set after one
of its disk drive was removed in the power off state.
When one of the disk drives is removed in power off state, the
RAID set state will change to “Incomplete State”. If user wants
to continue to work while the SAS RAID controller is powered
on, the user can use the “Activate Incomplete Raid Set” option